Single Cable Vertical Flame Test Apparatus
Place of Origin: China
Brand Name: HONGCE
Delivery Time: 30 days
Payment Terms: T/T
Certification: ISO/IEC 17025 Certificate
Model: VF-1
Burner: Φ7±0.05mm, made of brass
Burning angle: Tilt 45°±2°, Adjustable
Copper block: Ф9mm±0.01mm
Flame height: Inner flame:55±5mm, Outer flame:180±10mm
Single Cable Vertical Flame Test Apparatus
Standard:
IEC 60332-1-1 Tests on electric and optical fibre cables under fire conditions –Part 1-1: Test for vertical flame propagation for a single insulated wire or cable – Apparatus;
IEC 60332-1-2 Tests on electric and optical fibre cables under fire conditions –Part 1-2: Test for vertical flame propagation for a single insulated wire or cable – Procedure for 1 kW pre-mixed flame;
IEC 60332-1-3 Tests on electric and optical fibre cables under fire conditions –Part 1-3: Test for vertical flame propagation for a single insulated wire or cable – Procedure for determination of flaming droplets/particles.
Application:
Suitable for vertical burning test of single cable or optical cable products, determine the combustion characteristics of insulating materials.
Test sample:
Single cable or optical cable products.
Feature:
Using integral intake automatic ignition system, combustion time delay only 0.1s to ensure that the full combustion of the gas.
Parameters:
Working voltage |
220V/50Hz |
Control operation mode |
Electrical control, button operation |
Blast burner standard |
IEC60695-11-2 Annex A, Burner opening:Φ7±0.05mm, made of brass |
Gas flow and gas category |
Mixture gas: 650±30mL/min propane; 10±0.5L/min air, Dual flow meter adjustment |
Burning time |
9999X0.1S |
Burning angle |
Tilt 45°±2°, Adjustable |
Test flame calibration |
Temperature measuring copper head: 500W: Ф9mm±0.01mm, weight before drilling:10 ± 0 .05g |
Thermocouple: The American original Omega φ0.5 armour nickel-chromium/nickel aluminum wire K-Thermocouple, temperature resistance 1100° |
|
Distance between the bunsen burner port to temperature measuring copper block:95 mm |
|
Flame height: Inner flame:55±5mm, Outer flame:180±10mm |
|
Temperature rise time from 100±5°C to 700°±3°C 45±5s |
|
Combustion chamber |
WDH=300×450×1200±25㎜ |
Gas |
>95% propane or coal gas |
Test sample |
Length: 600±25㎜, distance from the bottom:50mm |
Fixed horizontal support of the sample |
2, distance:550mm |
Dimension |
WDH=700×450×1350㎜, weight about 120kg |
Guangzhou HongCe Equipment Co., Ltd
Tel:18826455520
WhatsApp: +86 18826455520
Skype : hongceauto@gmail.com
WeChat : +86 18826455520
Email:hongce@iectester.com
Address:Room 202, Building 42, No. 539, Shibei Industrial Road, Dashi Street, Panyu District, Guangzhou, Guangdong, China
智能分站
Copyright ©2016 Guangzhou HongCe Equipment Co., Ltd All Rights Reserved. 粤ICP备15039889号
Powerby:300.cn