How to check if the constant temperature chamber does not refrigerate

How to check if the constant temperature chamber does not refrigerate

  • Categories:Industry News
  • Author:
  • Origin:
  • Time of issue:2022-12-12 16:14
  • Views:

(Summary description)Check whether the alarm protection function is normal, whether the refrigeration compressor of the constant temperature chamber is started and running,

How to check if the constant temperature chamber does not refrigerate

(Summary description)Check whether the alarm protection function is normal, whether the refrigeration compressor of the constant temperature chamber is started and running,

  • Categories:Industry News
  • Author:
  • Origin:
  • Time of issue:2022-12-12 16:14
  • Views:
Information

  1. Check whether the alarm protection function is normal, whether the refrigeration compressor of the constant temperature test chamber is started and running, check the air pressure gauge of the refrigeration compressor, and check whether the internal refrigerant is leaking; Only then can the constant temperature and humidity test chamber be lowered normally;Ceramic silicone rubber cost

2. Check whether the cooling fan is operating normally, check whether the dust in the air inlet is too thick, check whether the internal circulation fan of the housing is operating normally, check the DC contactor of the refrigeration compressor and its overheating Check whether the flow protector is damaged; check whether the relay in the pipeline is turned on, check whether the intermediate relay of the heating system is damaged, and affect the cooling system;

3. Because part of the constant temperature chamber will adopt the cascade refrigeration method, if one of the refrigeration compressors cannot work normally, it will also cause the equipment to fail to normal down to check the automatic control system of the refrigeration compressor Whether it is working normally, check whether there is any sound in the operation of the compressor, or there is an abnormal working sound, these may cause failure to lower the position.

Keyword:

Other

Guangzhou HongCe Equipment Co., Ltd

Tel
Tel:18826455520
Email
WhatsApp: +86 18826455520
Email
Skype : hongceauto@gmail.com 
Email
WeChat : +86 18826455520 
Address
Address:Room 202, Building 42, No. 539, Shibei Industrial Road, Dashi Street, Panyu District, Guangzhou, Guangdong, China

智能分站

language
中国
韩国
韩国
韩国
韩国
韩国

Copyright ©2016  Guangzhou HongCe Equipment Co., Ltd All Rights Reserved. 粤ICP备15039889号

Powerby:300.cn