Horizontal-vertical Flame Test Apparatus IEC60695-11-3
1/1
Number of views:
1000

Horizontal-vertical Flame Test Apparatus IEC60695-11-3

This series of products adopt integral type inlet ignition system. The combustion time delays 0.1S thus to make sure the sufficient time of gas burning. They are with matte black background, multi-functional flame measure gauge, stainless steel of box full, large observation window, imported digital indicator of high precision, nice appearance. And they gather a number of advantages of similar products home and abroad.
Number of views:
1000
Product serial number
HVF-1/HVF-2/HVF-3
Quantity
-
+
1
Datils

Standard

UL94IEC60695-11-2, IEC60695-11-3, IEC60695-11-4, IEC60695-11-10, IEC60695-11-20.

Application

It simulates the influence of early-stage flame when there is a fire around the electric and electronic products, so that to judge the igniting danger degree. It is mainly used in plastic and other non-metallic material sample, solid material. It is also applicable in the Horizontal, vertical flammability test of the relative combustion characteristic of foam plastics whose density is no-less than 250kg/m according to ISO845 test method.

Test sample

It is also applicable in the Horizontal, vertical flammability test of the relative combustion characteristic of foam plastics whose density is no-less than 250kg/m according to ISO845 test method.

Feature:

This series of products adopt integral type inlet ignition system. The combustion time delays 0.1S thus to make sure the sufficient time of gas burning. They are with matte black background, multi-functional flame measure gauge, stainless steel of box full, large observation window, imported digital indicator of high precision, nice appearance. And they gather a number of advantages of similar products home and abroad.

 

Parameters

Parameters\Model

HVF-1

HVF-2

HVF-3Touch screen

Working voltage

220V/50Hz

220V/50Hz

220V/50Hz

Power/grade

50W or 500W

50W and 500W double power switching

50W and 500W double power switching

Control operation mode

Electrical control, button operation

Electrical control, button operation

PLC control, 7 inch color touch screen operation, with infrared remote control

Blast burner standard

IEC60695-11-3/IEC60695-11-4/10,UL94inner diameter:Φ9.5±0.3mm,length:100mmmade of brass

Gas pressure

0.1MPa

Gas flow

50W:105±5ml/min or 18±1mm;500W965±30ml/min or 117±3 mmflow meter adjustment

 U type pressure gauge back pressure water column height

50W:10mm;                           500W:125±5 mm

 

Test angle

50W: 0°,45°;                         500W: 20°

 

Burning time

0-9999X0.1S Can be preset

 

Burning times

0-9999 timesCan be preset

 

Residual flame/Residual glow

0-9999X0.1S Can be displayed

 

Test flame calibration

Temperature measuring copper head50WФ5.5mm±0.01mmweight before drilling 1.76 ± 0 .01 g500WФ9mm±0.01mmweight before drilling 10 ± 0 .05g

 

Thermocouple:The American original Omega φ0.5 armour nickel-chromium/nickel aluminum wire K-Thermocouple,temperature resistance 1100°

 

Distance between the bunsen burner port to temperature measuring copper block:50W: 10±1 mm; 500W: 55±1 mm

 

Flame height50W: 20±2mm(there is no internal and external flame);   500W: Inner flame:40±2mmOuter flame:125±10mm

 

Temperature rise time from100±2°to 700°±3°50W: 44±2S;  500W: 54±2S

 

Lighting

Equip with lighting in the test chamber, with control

 

Test chamber and dimension

 > 0.75 cubeblack inwallwith exhaust fan, dimension:1100*550*1200mm, 140kg

 